2.5 KVA 36 VDC
|
•
|
5 KVA 76 VDC
|
•
|
10 KVA 360 VDC
|
•
|
2.5 KVA 48 VDC
|
•
|
5 KVA 120 VDC
|
•
|
12 KVA 192 VDC
|
•
|
3 KVA 36 VDC
|
•
|
5 KVA 180 VDC
|
||
•
|
3 KVA 48 VDC
|
•
|
7.5 KVA 120 VDC
|
||
•
|
3.5 KVA 48 VDC
|
•
|
7.5 KVA 180 VDC
|
||
•
|
5 KVA 48 VDC
|
•
|
10 KVA 180 VDC
|
Description
|
2.5KVA
|
3KVA
|
3.5KVA
|
4KVA
|
5KVA
|
6KVA
|
7.5KVA
|
10KVA
|
12KVA
|
Back-Up Mode
|
|||||||||
Out Wave Form
|
Pure Sine Wave
|
||||||||
Nominal Battery Voltage
|
48V DC
|
48VDC
|
48VDC
|
48VDC
|
96V DC 120V DC 180V DC
|
120V DC 180V DC
|
120V DC 180V DC
|
180 VDC
360V DC
|
192V DC
|
Output Power factor
|
0.8
|
||||||||
No Load O/P Voltage
|
220v±5vc
|
220v±5vc
|
|||||||
O/P Frequency
|
50 Hz ±1Hz
|
||||||||
Maximum No Load Batt. Current
|
1.1A± 0.2A
|
||||||||
Full Load O/P Current
|
8.7A±
0.5A
|
10.5A±
0.5A
|
11.5A±
0.5A
|
13A±
0.5A
|
17A±
0.5A
|
21A±
0.5A
|
27A±
0.5A
|
34A±
0.5A
|
42A±
0.5A
|
Total Harmonic Distortion
|
<3%
|
||||||||
Low Battery Indication
|
10.5V +/-0.2V DC Per Battery (12V DC Each )
|
||||||||
Low Batt. Cut OFF
|
10.3V +/-0.2V DC Per Battery (12V DC Each )
|
||||||||
Mains Mode
|
|||||||||
Max. Charging Current
|
10A±1Hz
|
||||||||
Full Load O/P Current at Mains Mode
|
15A±1A
|
17A±1A
|
17.6A±
1A
|
19.5A±
1A
|
25A±1A
|
30A±1A
|
35A±1A
|
42A±1A
|
45A±1A
|
Boost Charging Voltage
|
14.2V =/-0.2V DC Per Battery (12V DC Each)
|
||||||||
Float Charging Voltage
|
13.2V =/-0.2V DC Per Battery (12V DC Each)
|
||||||||
Normal Mode
|
|||||||||
Input Voltage Range
|
100V to 280V AC ±10vAC
|
125V to 280V AC
|
|||||||
Change Over Time(mains to Inverter)
|
< 40ms
|
||||||||
Change Over Time(inverter to Mains)
|
<25ms
|
||||||||
UPS Mode
|
|||||||||
Input Voltage Range
|
180V to 260V AC ±5V AC
|
||||||||
Change Over Time(mains to Inverter)
|
<10ms
|
||||||||
Change Over Time(Inv. to mains)
|
<10ms
|
||||||||
Protections
|
|||||||||
Protections
|
Output not OK, Battery Voltage Low(4Autl Retries), Over Load (6 Auto Retries)
|
||||||||
Battery Over Charge, Over Temperature, Short Circuit, Mains MCB Tripped
|
|||||||||
Displays
|
|||||||||
Displays
|
Welcome Message, Capacity, Output Voltage, Output Frequency. Load Percentage
|
||||||||
Input Voltage and Frequency, Load Percentage, Battery Charging, Battery Voltage and All protections
|
|||||||||
Environmental Parameters
|
|||||||||
Operating Temperature
|
0-45 Deg.
|
||||||||
Acoustic Noise at 1 Mtr.
|
<45 dB
|
||||||||
Relative Humidity
|
Max 95 % non – Condensing
|
||||||||
Thermal Management
|
Integrated Cooling (Fan & Heat Sink)
|
||||||||
Weight and Dimensions
|
|||||||||
With Packing LXWXH in mm
|
470x
440x
610
|
470x
440x
610
|
470x
440x
610
|
470x
440x
610
|
500x
495x
660
|
500x
495x
660
|
600x
500x
740
|
600x
500x
740
|
600x
500x
740
|
Without Packing LXWXH in mm
|
310x
290x
450
|
310x
290x
450
|
310x
290x
450
|
310x
290x
450
|
350x
300x
540
|
350x
300x
540
|
550x
350x
660
|
550x
350x
660
|
550x
350x
660
|
Net Weight
|
29Kg
|
32Kg
|
32Kg
|
45Kg
|
54Kg
|
54Kg
|
78Kg
|
89Kg
|
104Kg
|
GrossWeight
|
36Kg
|
39Kg
|
39Kg
|
49Kg
|
58Kg
|
58Kg
|
89Kg
|
100Kg
|
115KG
|
Application
|
Load
|
3KV
|
5Kv
|
7.5kVA
|
10KVA
|
12KVA
|
Petroleum Outlet
|
Fan
|
1
|
4
|
5
|
5
|
5
|
Tube Light
|
2
|
4
|
5
|
8
|
8
|
|
Petrol Filling Machine
|
1
|
2
|
3
|
4
|
5
|
|
Institute
|
Fan Only
|
30
|
50
|
75
|
100
|
110
|
Fan
|
18
|
35
|
55
|
70
|
75
|
|
Tube Light
|
15
|
20
|
35
|
40
|
50
|
|
Browsing Center
|
A.C
|
-
|
1
|
1
|
2
|
2
|
Fan
|
5
|
4
|
8
|
8
|
10
|
|
Tube Light
|
5
|
4
|
8
|
8
|
10
|
|
Computer
|
5
|
2
|
6
|
6
|
6
|
|
Browsing Center
|
Fan
|
5
|
10
|
12
|
20
|
25
|
Tube Light
|
5
|
10
|
12
|
20
|
25
|
|
Computer
|
5
|
8
|
12
|
15
|
20
|
|
Corporate Bldg.
|
A.C
|
-
|
1
|
1
|
2
|
2
|
Fan
|
18
|
8
|
12
|
16
|
20
|
|
Tube Light
|
15
|
8
|
12
|
16
|
20
|