Specified Parameters
|
Normal mode
|
UPS Mode
|
||
Voltage:
|
||||
- Mains AC lower voltage cut
|
100 ± 5V
|
180 ± 5 V
|
||
- Mains AC lower recovery
|
110 ± 5V
|
190 ± 5 V
|
||
- Mains AC Higher voltage cut
|
280 ± 5 V
|
265 ± 5 V
|
||
- Mains AC Higher recovery
|
270 ± 5 V
|
255 ± 5 V
|
||
Battery charging voltage range
|
110V AC to 280V AC
|
180V AC to 265V AC
|
||
Output voltage without load
|
230 ± 3V
|
230 ± 3V
|
||
Change over time
|
Approx 25 milli- sec
|
< 10 milli-sec
|
||
Battery Charging:
|
400VA
|
650VA
|
800VA
|
1400VA
|
No. of Batteries
|
Single
|
Single
|
Single
|
Double
|
‘Quick Charging’ Current
|
5 ± 1 amps
|
11± 1 amps
|
12 ± 1 amps
|
12 ± 1 amps
|
‘Normal Charging’ Current
|
( No option)
|
8 ± 1 amps
|
9 ± 1 amps
|
9 ± 1 amps
|
‘Boost Charging’ voltage
|
14.4 ± 0.2 V per battery ( Same in Quick Charge & Normal Charge)
|
|||
‘Float Charging’ voltage
|
13.8 ± 0.2 V per battery ( Same in Quick Charge & Normal Charge)
|
|||
Battery lower voltage cut-off
|
10.2 ± 0.2 V (Per Battery)
|
|||
Charging methodology
|
Constant current followed by constant voltage
|
|||
Output Wave form
|
Pure sine wave
|
|||
Output frequency
|
Same as input when AC mains available & 50.0 ± 0.5 Hz on UPS
|
|||
Efficiency
|
AC to DC : >95% & DC to AC : >80%
|
|||
Operating Environment
|
-250 C to + 550 C
|
|||
LED indications
|
Mains, Charging, UPS ON, Low battery & Over load
|
|||
Audible alarm
|
Low battery, Over load & Short circuit
|
|||
Protections:
|
||||
Over load
|
100 ± 5% load on UPS(auto reset if reduce the load with in 3 re-tries)
|
|||
Over Charge
|
Protects the battery from overcharging by controlling the charging current & voltage.
|
|||
Short Circuit
|
Shutdown when AC mains is not there and AC fuse blown when AC mains is available (Manual reset)
|
|||
Thermal shutdown
|
Above 930 C inside the unit
|
|||
Battery reverse polarity
|
Protects the UPS and DC fuses blown on PMB
|
|||
Battery deep discharge
|
Protects the battery from deep discharge having cut-off at 10.2 ± 0.2 V
|
|||

Tribal iACE 400
|
||
Available Colours
|
Black & White
|
|
Option 1
|
Option 2
|
|
Computer
|
1
|
-
|
Tube light
|
1
|
2
|
Fan
|
-
|
1
|
TV
|
-
|
-
|

Tribal iACE 650
|
||
Available Colours
|
Black & White
|
|
Option 1
|
Option 2
|
|
Computer
|
1
|
-
|
Tube light
|
2
|
3
|
Fan
|
2
|
3
|
TV
|
-
|
1
|


Tribal iACE 800
|
||
Available Colours
|
Black & White
|
|
Option 1
|
Option 2
|
|
Computer
|
1
|
-
|
Tube light
|
4
|
3
|
Fan
|
3
|
3
|
TV
|
-
|
1
|
Refrigerator
|
-
|
1
|
Tribal iACE 1400
|
||
Available Colours
|
Black & White
|
|
Option 1
|
Option 2
|
|
Computer
|
2
|
-
|
Tube light
|
4
|
4
|
Fan
|
4
|
3
|
TV
|
-
|
1
|
Refrigerator
|
-
|
1
|