Specified Parameters
|
Normal mode
|
UPS Mode
|
|
1. Voltage:
|
|||
- Mains AC lower voltage cut
|
180 ± 5V
|
100 ± 5 V
|
|
- Mains AC lower recovery
|
190 ± 5V
|
110 ± 5 V
|
|
- Mains AC Higher voltage cut
|
265 ± 5 V
|
280 ± 5 V
|
|
- Mains AC Higher recovery
|
255 ± 5 V
|
270 ± 5 V
|
|
2. Battery charging voltage range
|
180V AC to 265V AC
|
110V AC to 280V AC
|
|
3. Output voltage without load
|
230 ± 3V
|
230 ± 3V
|
|
4. Transfer time (Mains Power to Battery Mode)
|
< 10 milli-sec
|
Approx. 25 milli-sec
|
|
5. Battery Charging:
|
650VA
|
800VA
|
|
(Model: TRIBAL ITALIA 650)
|
(Model: TRIBAL ITALIA 800)
|
||
No. of Batteries
|
Single
|
Single
|
|
‘Quick Charging’ Current
|
11 ± 1 amps
|
12 ± 1 amps
|
|
‘Normal Charging’ Current
|
8 ± 1 amps
|
9 ± 1 amps
|
|
‘Boost Charging’ voltage
|
14.4 ± 0.2 V per battery (Same in Quick Charge & Normal Charge)
|
||
‘Float Charging’ voltage
|
13.8 ± 0.2 V per battery (Same in Quick Charge & Normal Charge)
|
||
Battery lower voltage cut-off
|
10.2 ± 0.2 V (Per Battery)
|
||
Charging methodology
|
Constant current followed by constant voltage
|
||
6. Output Wave form
|
Pure sine wave
|
||
7. Output frequency
|
Same as input when AC mains available & 50.0 ± 0.5 Hz on UPS
|
||
8. Special Features
|
|||
Efficiency
|
AC to DC : >95%
|
||
DC to AC : >80%
|
|||
9. Environmental
|
|||
Operating Temperature
|
-250 C to +550 C
|
||
Relative Humidity
|
0-95% non-condensing
|
||
10.LED indications on Front Panel
|
Mains, Charging, UPS ON, Low battery & Over load
|
||
11.Audible alarm
|
Low battery, Over load & Short circuit
|
||
12. Protections:
|
|||
Over load
|
100 + 5% load on UPS(auto reset if reduce the load with in 3 re-tries)
|
||
Includes 6A AC fuse dedicated for AC output loads
|
|||
Over Charge
|
Protects the battery from overcharging by controlling the charging current & voltage.
|
||
Short Circuit
|
Shutdown when AC mains is not there and AC fuse blown when AC mains is available (Manual reset)
|
||
Thermal shutdown
|
Above 930 C inside the unit
|
||
Battery reverse polarity
|
Protects the UPS and DC fuses blown on PMB
|
||
Battery deep discharge
|
Protects the battery from deep discharge having cut-off at 10.2 ± 0.2 V
|
||
13. Outlet Quantity
|
1 Mains AC outlet, 3 Additional Outlets for use of Mobile Charger, Laptops, Desk Tops, etc.
|
||
14. Physical
|
650VA
|
800VA
|
|
(Model: TRIBAL ITALIA 650)
|
(Model: TRIBAL ITALIA 800)
|
||
Unit Dimensions (H x W x L/mm)
|
521 x 341 x 670
|
521 x 341 x 670
|
|
Unit weight (kg)
|
16.98kgs
|
19.10kgs
|
|
Receptacle Colour
|
Zet black & White
|
Zet black & White
|
|
Shipping Dimensions ( H x W x L / mm)
|
545 x 370 x 705
|
545 x 370 x 705
|
|
Shipping weight (kg)
|
24.88kgs
|
27.00kgs
|
|


TRIBAL ITALIA 650
|
||
Available Colours
|
Black & White
|
|
Loads
|
Option-1
|
Option-2
|
Computer
|
-
|
1
|
Tube light
|
3
|
2
|
CFL
|
3
|
4
|
Fan
|
2
|
1
|
TV
|
1
|
-
|
TRIBAL ITALIA 800
|
||
Available Colours
|
Black & White
|
|
Loads
|
Option-1
|
Option-2
|
Computer
|
-
|
1
|
Tube light
|
4
|
3
|
CFL
|
3
|
3
|
Fan
|
3
|
2
|
TV
|
1
|
-
|